Hook up wood stove to furnace. Linking indoor woodstove furnace to existing gas furnace ductwork.

Hook up wood stove to furnace Rating: 9,3/10 1930 reviews

Find out how to Install a heat exchanger for an Outdoor Wood Burning Furnace

hook up wood stove to furnace

In the basement it usually gets above 80 degrees that transmitts to keeping the above floor in the range of about 70F with no extra use of power from the furnace fan. It might seem too small at first, but it will fit. I didn't have it installed, and I want to understand if it's been done properly, and how to use it properly. All of the electrical parts on our outdoor wood burning furnaces are U. With the pump running turn the thermostat up to 90 F so that the pump comes on , simply close the brass valve on the return line quickly, holding it for 3-4 seconds.

Next

How to Hook a Stovepipe to Wood

hook up wood stove to furnace

Just a loss of electricity can cause a problem and that is the biggest concern I have. I'm wondering if it would work better to pipe it into his return duct and add a relay to turn on the furnace fan to distribute the air. We will be happy to assist you any way we can with installing an outdoor wood boiler! Use a tape measure to identify the difference if needed. Though there is nothing wrong or broken with the stove, and nothing wrong with draft flow, etc. But people have done it and got it to work for them.

Next

Linking indoor woodstove furnace to existing gas furnace ductwork.

hook up wood stove to furnace

You'll have to make it removable or add some type of an access door. Also be aware not to connect the duct to the stove with screws as you still need to get to the heat exchanger cleaning rod. For the record, a second thermostat is not even needed because the wood furnace has twin 800cfm blowers producing plenty of air flow. It will also surely void the insurance on the building. Many garages or shops use an air handler like the one below, with a built-in. The Central Boiler outdoor furnace is located outside, typically 30 to 200 feet but as far as 500 feet away from your home or building, and works with any existing heating system.


Next

Outdoor Wood Boile Furnace Hookup Kits

hook up wood stove to furnace

The reason the stove manufacturers don't want any connections to duct work is to protect the masses of idiots out there. Float Level After priming and starting the circulation pump and bleeding the heat exchanger see next section , let the boiler heat up and run for 24 hours then top off the water if needed. Slide the heat exchanger carefully into the plenum to check the fit again. This is always the best way because putting the heat exchanger in the return duct where the filter is will cause hot air to blow over the fan -heating it up instead of cooling it down. We've also got a wood-burning stove adjacent to the furnace. The large end fits on the flange.

Next

Why would you hook up the heat output of a wood stove to the cold air return on an electric forced

hook up wood stove to furnace

Hello everyone, As the new guy, I expect to get tossed around a bit but here goes. All Pleasant Hearth wood burning stoves feature a brick lined. Wiring direct to the blower and by-passing the control board and relays involved would perhaps be a bad thing. I use a wood stove to heat the farm house, with two propane fired furnaces for backup. There is also the valve at the bottom of the hot line just before it goes in the hot water heat exchanger. The heat exchanger must be installed so that it is airtight.

Next

Why would you hook up the heat output of a wood stove to the cold air return on an electric forced

hook up wood stove to furnace

Open the drain valve to keep the float indicator at the bottom of the rubber cap. For a forced air system, run the line from the pump first to the heat exchanger for the domestic hot water then to the one in the furnace plenum. If those radiators are hooked up to a pressurized system then maybe a direct hook up won't work. If they decide to post I will let them put there own 2 cents in. The furnace supplies enough heat to warm my entire 2500 sq. The wall thermostat will keep your house from getting too cold by turning on the electric furnace.

Next

This is how I have my outside wood furnace system (with photos)

hook up wood stove to furnace

The scary part is the plan I have is the simplified version! This is a good ideal because you will get the whole core inside the ductwork. You can install shorter or longer sections onto the top of the stove depending on your needs. Related question: My mid-efficiency furnace has a return duct opening right where the return-duct enters the furnace. Run those 2 wires to the new thermostat and attach to the R and G terminals. A heat pump only heats air to somewhere around 100 to 110 degrees, but a regular, say, gas furnace is going to heat it up to like around 120 to 140 degrees.


Next

Outdoor Wood Boile Furnace Hookup Kits

hook up wood stove to furnace

Crimp the sheet metal to the edge of the heat exchanger item G using channel-lock pliers. I pigtailed a red wire and green wire from the gas furnace thermostat and attached them to the second thermostat. Filling the Boiler with Water Inspection: Before filling, inspect the pump shaft by removing the large silver screw to expose the top of the shaft and turn back and forth with a screw driver to make sure the shaft was not broken during shipping. Be completely sure about the correct depth needed before the insulated pex pipe is installed underground. Here is my thread on my setup. The outdoor furnace is designed to work with any existing heating system.

Next